Product introduction:
Simple Introduction:
1. 200mA X-ray unit with 4ways position bed
2. 4*90 angle rotary column
3. x-ray unit.
200mA X-ray MachineTechnical data
Item | Content | Index |
Demand of power supply | Voltage frequency | 380V/220V±10 50Hz±0.5Hz |
Internal resistance | 220V:0.25Ω | |
Power supply | Adjustable range | 380V±10at380V; 220V±10at220V being adjustable continuously |
Radiographic | Voltage | 50-100kV |
Current |
Small focus 50mA,100mA Big focus 50,100,150,200mA |
|
Time | 0.04-6.3s,20grades together grading according to R10coefficient | |
High-voltage generator | Capacity | 15kVA(instantaneous) |
Max DC output voltage | 100kV | |
Max DC output current | 200mA | |
X-ray tube | Model | XD51-20.40/125 |
Focus |
Small focus:1×1mm, Big focus:2×2mm |
|
Radiographic table | Table face(L×W×H) | 2000mm×710mm×700mm |
Moving range of table face | 620mm×200mm | |
Ray-filter |
Travel (in length):620mm (in breadth):200mm |
|
Grid density N28 | ||
Convergence distance of 100cm | ||
Grid ratio R8 | ||
Pillar of X-ray tube unit | Moving in length along radiographic table | 1800mm or 1600mm |
Distance to ground as moving up and down (along upright post) | 630mm~1750mm | |
Rotary around the center of cross arm | ±180º | |
Rotary around the shaft line of X-ray annular tubes |
-10º~60º~+120º | |
Max size of cassette for radiography | 356mm×432mm(14"×17") |
Focus of X-ray tube |
Photograph Current (mA) |
Max photograph voltage (kvp) |
Max allowable exposure time |
Small focus | 50 | 100 | 4.0 |
100 | 100 | 1.0 | |
Big focus | 50 | 100 | 6.3 |
100 | 100 | 3.2 | |
150 | 95 | 2.0 | |
200 | 90 | 1.0 |
Main Features:
1.Single bed with single bulb
2.High visual and operational Console with tube voltage ,tube current, and photographtime dispaly on the LCD monitor
3.Prestore 8 kinds of photograph parameters and select, modify,store the parameters under condition of choice
4.auto power and voltage control,kv continous adjustable ,auto Fault Alarm
5.Premier high voltage with high power SCR zero control circuit
6.X-RAY subassembles is equiped with Tangential-pipe kits
7.photograph bed, column, Vibration Filter limiter intergrated equipment without necessity of up-and-down tunnel
8.photography bed can be moved both laterally and vibrally Column can turn 4*90
9.Function of load chains, exposure time control ,Start and stop rptating anode, Preheat filament, subassembles tempreture control, and so on.
400-686-9889
ADDRESS:565 jujiaqiao Road, Pudong New Area, Shanghai, China
EMAIL:2277936265@qq.com
TEL:021-62500690